| Residential
Roofing Replacement Requirements |
|
RESIDENTIAL ROOFING
REPLACEMENT REQUIREMENTS
1. General: Shingles shall be applied only to solidly
sheathed roofs; all delaminated/rotted plywood must be replaced.
Shingles shall be applied according to manufacturer's printed
instructions and Section R905 and as amended per the 2003 ICC
International Residential Code for One-and Two family dwellings.
If the existing roof has two or more layers of any type of
roof covering system, a "tear-off" (removal) of the
existing covering system needs to be done to provide a weather
resistant envelope and ensure that the structural support of the
roof is safeguarded.
2. Slope: Determined by rise & run, for example 4"
rise in 12" run, equals 4/12 slope or pitch.
Fee: Minimum $33.00 up to $3,300.00 + $6.25/$1,000.00 over
$3,300.00
SECTION R905 REQUIREMENTS FOR ROOF
COVERINGS
R905.1 Roof covering application. Roof coverings shall be
applied in accordance with the applicable provisions of this
section and the manufacturer's installation instructions.
R905.2.1 Asphalt shingles. The installation of asphalt
shingles shall comply with the provisions of this section.
R905.2.1 Sheathing requirements. Asphalt shingles shall be
fastened to solidly sheathed decks.
R905.2.2 Slope. Asphalt shingles shall only be used on roof
slopes of two units vertical in 12 units horizontal (2:12) or
greater. For roof slopes from two units vertical in 12 units
horizontal (2:12) up to four units vertical in 12 units
horizontal (4:12), double underlayment application is required
in accordance with Section R905.2.7.
R905.2.3 Underlayment. Unless otherwise noted, required
underlayment shall conform with ASTM D 226. Type I, or ASTM D
4869, Type I.
Self -adhering polymer modified bitumen sheet shall comply
with ASTM D 1970.
R905.2.4 Asphalt shingle. Asphalt shingles shall have
self-seal strips or be interlocking, and comply with ASTM D 225
or D 3462.
R905.2.5 Fasteners. Fasteners for asphalt shingles shall be
galvanized steel, stainless steel, aluminum or copper roofing
nails, minimum 12 gage [0.105 inch (2.67 mm)] shank with a
minimum 3/8-inch (9.5 mm) diameter head, ASTM F 1667, of a
length to penetrate through the roofing materials and a minimum
of ¾ inch (19.1 mm) into the roof sheathing. Where the roof
sheathing is less than ¾ inch (19.1 mm) thick, the fasteners
shall penetrate through the sheathing. Fasteners shall comply
with ASTM F 1667.
R905.2.6 Attachment. Asphalt shingles shall have the minimum
number of fasteners required by the manufacturer. For normal
application, asphalt shingles shall be secured to the roof with
not less than four fasteners per strip shingle or two fasteners
per individual shingle.
Section R905.2.7.1 Ice protection shall be amended to read:
All asphalt shingle roofs shall have ice protection. The ice
barrier shall consist of at least two layers of underlayment
cemented together or of a self-adhering polymer modified
bituminous sheet in lieu of normal underlayment and shall extend
from the eave's edge to a point at least 24 inches from the
inside of the exterior wall line and at all valleys 24 inches
from the center line of the valley.
R905.2.8.2 Valleys. Shall comply with manufactures
installation instructions and Table R905.2.8.2 (Table for Valley
living materials).
NOTE: Recommended as good construction practice-but not
required:
If a homeowner chooses to install a roof on their own, or
with the help of family or friends, it is recommended that
proper insurance coverage be available.
Be advised that a Roofing Contractor is required to have a
License from the State of Illinois (with insurance coverage) on
file with the Building Department before we issue a permit.
An aluminum drip edge at roof perimeter is recommended.
Revised 1/1/08
Government
| Services | Community
| Development
| Reference
Desk
Search | Site Map
| Home
The Village of Wheeling,
Illinois
255 West Dundee Road
Wheeling, IL 60090
(847) 459-2600
Click here to send feedback
to the Village of Wheeling.
All information © 2007 Village of Wheeling, Illinois
Site Use
Policy
Site Design/Development by

|